Key issues:
- Ensure environmental Nuclear emission standards are achieved.
- Thermal Inertia through concrete walls.
- Air and Helium mixture mass fraction concentration variation throughout building.
- Pressure and Temperature variations during accident scenarios.
- Determine if max gas pressures are controlled by the opening sizes or room volumes.
Methodology:
- Model the building and perform analysis of the Pressure Relief System.
- Test Confinement & Containment Scenarios.
- Test Pressure Relief System scenarios.