Dynamic Response

Key issues:

  • Create a Primary cycle simulation for what if studies.
  • Analysis of ambient effects on condensers.
  • Optimisation of primary cycle efficiency.

Methodology:

  • Flownex Rankin cycle is setup with two phase steam.
  • Create Human machine interface for network, to quickly run through various what if studies.

Solution:

  • The model was used to analyze overall system data on a basic level, bringing into account System Efficiencies, Temperature, Pressure and Quality distribution.
  • Various what if studies were performed to ensure optimal efficiency achieved.